217 research outputs found

    Photocathodes for a post-processed imaging array

    Get PDF
    Preliminary results of a photon detector combining a Micromegas like multiplier coated with a UV-sensitive CsI photocathode are described. The multiplier is made in the CMOS compatible InGrid technology, which allows to post-process it directly on the surface of an imaging IC. This method is aimed at building light-sensitive imaging detectors where all elements are monolithically integrated. We show that the CsI photocathode deposited in the InGrid mesh does not alter the device performance. Maximum gains of ~6000 were reached in a singlegrid element operated in Ar/CH4, with a 2% Ion Back Flow fraction returning to the photocathode

    A Radiation Imaging Detector Made by Postprocessing a Standard CMOS Chip

    Get PDF
    An unpackaged microchip is used as the sensing element in a miniaturized gaseous proportional chamber. Thisletter reports on the fabrication and performance of a complete radiation imaging detector based on this principle. Our fabrication schemes are based on wafer-scale and chip-scale postprocessing.\ud Compared to hybrid-assembled gaseous detectors, our microsystem shows superior alignment precision and energy resolution, and offers the capability to unambiguously reconstruct 3-D radiation tracks on the spot.\u

    The ultimate performance of the Rasnik 3-point alignment system

    Full text link
    The Rasnik system is a 3-point optical displacement monitor with sub-nanometer precision. The CCD-Rasnik alignment system was developed in 1993 for the monitoring of the alignment of the muon chambers of the ATLAS Muon Spectrometer at CERN. Since then, the development has continued as new CMOS imaging pixel chips became available. The system's processes and parameters that limit the precision have been studied in detail. We conclude that only the quantum fluctuations to which the light level content of sensor pixels are subject to, is limiting the spatial resolution. The results of two Rasnik systems are compared to results from simulations, which are in good agreement: the best reached precision of \SI{7}{pm/\sqrt{Hz}} is reported. Finally, some applications of high-precision Rasnik systems are set out

    Optical properties of silicon rich silicon nitride (SixNyHz) from first principles

    Full text link
    The real and imaginary parts of the complex refractive index of SixNyHz have been calculated using density functional perturbation theory. Optical spectra for reflectivity, adsorption coefficient, energy-loss function (ELF), and refractive index, are obtained. The results for Si3N4 are in agreement with the available theoretical and experimental results. To understand the electron energy loss mechanism in Si rich silicon nitride, the influence of the Si doping rate, of the positions of the dopants, and of H in and on the surface on the ELF have been investigated. It has been found that all defects, such as dangling bonds in the bulk and surfaces, increase the intensity of the ELF in the low energy range (below 10 eV). H in the bulk and on the surface has a healing effect, which can reduce the intensity of the loss peaks by saturating the dangling bonds. Electronic structure analysis has confirmed the origin of the changes in the ELF. It has demonstrated that the changes in ELF is not only affected by the composition but also by the microstructures of the materials. The results can be used to tailor the optical properties, in this case the ELF of Si rich Si3N4, which is essential for secondary electron emission application

    Screening for type 2 diabetes in a high-risk population: Study design and feasibility of a population-based randomized controlled trial

    Get PDF
    Background: We describe the design and present the results of the first year of a population-based study of screening for type 2 diabetes in individuals at high risk of developing the disease. High risk is defined as having abdominal obesity. Methods. Between 2006 and 2007, 79,142 inhabitants of two Dutch municipalities aged 40-74 years were approached to participate in screening. Eligible participants had a self-reported waist circumference of 80 cm for women and 94 cm for men, and no known pre-existing diabetes. Of the respondents (n=20,578; response rate 26%), 16,135 were abdominally obese. In total, 10,609 individuals gave written informed consent for participation and were randomized into either the screening (n=5305) or the control arm (n=5304). Participants in the screening arm were invited to have their fasting plasma glucose (FPG) measured and were referred to their general practitioner (GP) if it was 6.1 mmol/L. In addition, blood lipids were determined in the screening arm, because abdominal obesity is often associated with cardiovascular risk factors. Participants in both arms received written healthy lifestyle information. Between-group differences were analyzed with Chi-square tests and logistic regression (categorical variables) and unpaired t-tests (continuous variables). Results: The screening attendance rate was 84.1%. Attending screening was associated with age at randomization (OR=1.03, 95% CI 1.02-1.04), being married (OR=1.57, 95% CI 1.33-1.83) and not-smoking currently (OR=0.52, 95% CI 0.44-0.62). Of the individuals screened, 5.6% had hyperglycemia, and a further 11.6% had an estimated absolute cardiovascular disease risk of 5% or higher, according to the Systematic Coronary Risk Evaluation risk model. These participants were referred to their GP. Conclusions: Self-reported home-assessed waist circumference could feasibly detect persons at high risk of hyperglycemia or cardiovascular disease. Continuation of the large-scale RCT is warranted to test the hypothesis that targeted population-based screening for type 2 diabetes leads to a significant reduction in cardiovascular morbidity and mortality

    A UV Sensitive Integrated Micromegas with Timepix Readout

    Get PDF
    This article presents a detector system consisting of three components, a CMOS imaging array, a gaseous-detector structure with a Micromegas layout and a UV-photon sensitive CsI reflective photocathode. All three elements have been monolithically integrated using simple post-processing steps. The Micromegas structure and the CMOS imaging chip are not impacted by the CsI deposition. The detector operated reliably in He/isobutane mixtures and attained charge gains with single photons up to a level of 6 \cdot 10^4. The Timepix CMOS array permitted high resolution imaging of single UV-photons. The system has an MTF50 of 0.4 lp/pixel which corresponds to app. 7 lp/mm.Comment: 4 pages with 8 figures. Submitted to Nucl. Instr. and Meth. A (Elsevier) for proceedings of VCI 2010

    The alignment of the C3 Accelerator Structures with the Rasnik alignment system

    Full text link
    The Rasnik 3-point alignment system, now widely applied in particle physics experiments and in the instrumentation of gravitational wave experiments, can be used as N-point alignment system by daisy chain N individual 3-point systems. The conceptual implementation of Rasnik chains in C3 is presented. The proper operation of a laser diode and a CMOS image sensor in liquid nitrogen has been verified. Next plans for testing a small but complete system, immersed in liquid nitrogen, are presented

    A simple microscopy setup for visualizing cellular responses to DNA damage at particle accelerator facilities

    Get PDF
    Cellular responses to DNA double-strand breaks (DSBs) not only promote genomic integrity in healthy tissues, but also largely determine the efficacy of many DNA-damaging cancer treatments, including X-ray and particle therapies. A growing body of evidence suggests that activation of the mechanisms that detect, signal and repair DSBs may depend on the complexity of the initiating DNA lesions. Studies focusing on this, as well as on many other radiobiological questions, require reliable methods to induce DSBs of varying complexity, and to visualize the ensuing cellular responses. Accelerated particles of different energies and masses are exceptionally well suited for this task, due to the nature of their physical interactions with the intracellular environment, but visualizing cellular responses to particle-induced damage - especially in their early stages - at particle accelerator facilities, remains challenging. Here we describe a straightforward approach for real-time imaging of early response to particle-induced DNA damage. We rely on a transportable setup with an inverted fluorescence confocal microscope, tilted at a small angle relative to the particle beam, such that cells can be irradiated and imaged without any microscope or beamline modifications. Using this setup, we image and analyze the accumulation of fluorescently-tagged MDC1, RNF168 and 53BP1—key factors involved in DSB signalling—at DNA lesions induced by 254 MeV α-particles. Our results provide a demonstration of technical feasibility and reveal asynchronous initiation of accumulation of these proteins at different individual DSBs
    corecore